The block-oriented simulation system BORIS enables the linkage to real processes via different kinds of hardware drivers. It has to be seperated between two types of hardware:
Is shown as a Wasco USB Communication Port COMx in your Windows ® Device Manager. This is a CDC device (Communications Device Class), that is adressed via a virtual COM port. The software access to this virtual COM port operates like a normal COM interface of default Windows ® drivers, and it is not necessary to install any additional drivers. International Home Site. Welcome to Lauterbach – Microprocessor Development Tools: Lauterbach is the world's largest producer of complete, modular and upgradeable microprocessor development tools worldwide with experience in making world class debuggers and real-time trace since 1979.
- PC-internal cards which have direct access to the PC-bus. These cards are especially recommended for time critical problems.
- External hardware modules which communicate with the PC via e. g. the serial RS232- or the parallel interface or USB or Ethernet. This group includes also SPS and bus driven modules.
- Automation systems
- Other drivers…
Please consider that all technical data listed below are based upon specifications given by the concerning distributors and are without liability. The list is updated permanently; so if your type of hardware is not yet included, just call us!
The prices for the drivers depend on the hardware as well as on the number of users. Drivers for modules marked by can be downloaded free of charge from the download area. Please refer to our price lists for current prices of all products!
Drivers for PC-internal cards / USB modules
Card / module type | Distributor | Analog inputs | Analog outputs | Digital inputs | Digital outputs | free digital channels | Counters |
---|---|---|---|---|---|---|---|
ADDI-DATA PA 310 | ADDI-DATA | 16 | 6 | 0 | 0 | 2 | 0 |
PCI 9118 | ADLINK | 16 | 2 | 4 | 4 | 0 | 0 |
Advantech | Advantech | all modules are completely supported | |||||
DAC6214 (PCA900) | Amira | 6 | 2 | 4 | 4 | 0 | 0 |
DAC98 (PCA902) | Amira | 8 | 2 | 8 | 8 | 0 | 2 |
RTI-800/815 | Analog Devices | 16 | 2 | 8 | 8 | 0 | 0 |
08-0-39 | Bitzer Digitaltechnik | 8 | 2 | 0 | 4 | 24 | 0 |
Schetter BMC | BMC Messsysteme | all modules which are supported by the BMCSAD interface | |||||
DT 98xx USB-Messmodule | DATA TRANSLATION | all modules are completely supportedt | |||||
8-Channel-DA-Card | Decision Computer | 0 | 8 | 0 | 0 | 0 | 0 |
PI-216 | Decision Computer | 16 | 0 | 8 | 8 | 0 | 3 |
PC 73C | Eagle Technology | 8 | 0 | 8 | 8 | 0 | 0 |
ELV-ADA-8 | ELV (Selbstbau) | 8 | 8 | 0 | 0 | 0 | 0 |
PADAC | IBES-Electronic | 8 | 2 | 8 | 8 | 0 | 0 |
PCI-1202 | ICPDAS | 32 | 2 | 16 | 16 | 0 | 0 |
IED-ParaMio | IED GmbH | 16 | 3 | 16 | 16 | 0 | 0 |
PCI-20098 | Intelligent Instr. | 16 | 0 | 0 | 0 | 16 | 2 |
PCI-20428W-x | Intelligent Instr. | 16 | 2 | 8 | 8 | 0 | 1 |
200377W Board | Intelligent Instr. | 16 | 0 | 8 | 8 | 0 | 2 |
DAQ Board 2000 | IOTECH | 16 | 2 | 0 | 0 | 40 | 4 |
DAS16-330 | Keithley | 16 | 0 | 4 | 4 | 0 | 2 |
DAS-1601/1602 | Keithley | 16 | 2 | 4 | 4 | 24 | 2 |
DAC 416 | Kolter Electronic | 0 | 4 | 0 | 2 | 0 | 0 |
IA100 | Locamation B. V. | 16 | 8 | 0 | 0 | 0 | 0 |
ME-30 | Meilhaus Electronic | 16 | 4 | 0 | 0 | 24 | 1 |
ME-300 | Meilhaus Electronic | 16 | 4 | 0 | 0 | 24 | 0 |
ME-3000 | Meilhaus Electronic | 16 | 4 | 0 | 0 | 32 | 3 |
PC 30A | Meilhaus Electronic | 16 | 4 | 0 | 0 | 24 | 0 |
ME-46xx | Meilhaus Electronic | all modules are completely supported | |||||
ME-PCard 24di | Meilhaus Electronic | 8 | 0 | 4 | 4 | 0 | 0 |
ME-PCard 24di/12di | Meilhaus Electronic | 8 | 0 | 4 | 4 | 0 | 0 |
ME-PCard 24/16di | Meilhaus Electronic | 8 | 0 | 4 | 4 | 0 | 0 |
PC-30DS4 | Meilhaus Electronic | 16 | 4 | 0 | 0 | 8 | 0 |
Wasco ADIODA-12 Extended | Messcomp Datentechnik | 32 | 4 | 0 | 0 | 24 | 3 |
Wasco ADIODA-12 LAP | Messcomp Datentechnik | 8 | 1 | 0 | 0 | 24 | 3 |
Wasco ADIODA-12 Standard | Messcomp Datentechnik | 16 | 2 | 0 | 0 | 24 | 3 |
Wasco ADIODA-PCI12 LAP | Messcomp Datentechnik | 8 | 1 | 0 | 0 | 24 | 3 |
Wasco ADIODA-12 Low Cost | Messcomp Datentechnik | 8 | 0 | 0 | 0 | 24 | 3 |
ADIODA-PCIF12/extended | Messcomp Datentechnik | 64 | 1 | 16 | 16 | 0 | 3 |
National Instruments | National Instruments | almost all modules are supported |
Bleile Datentechnik Port Devices Driver Ed
On request we program drivers for other cards / modules!
Drivers for external modules

Bleile Datentechnik Port Devices Driver License Test
We offer ready-to-use drivers for the following hardware modules:
Module type | Manufacturer / Distributor | Connection |
---|---|---|
ADAM modules | Advantech | RS-232 / Ethernet |
Arduino-Board | Arduino | USB / Ethernet |
LabMap®-Softwarebus | cbb-Software GmbH | - |
8-fach-Relaiskarte serial | CONRAD Electronic | RS-232 |
TopMessage-System | DELPHIN | RS-232 |
COMENIUS-Interface | ELWE-Lehrsysteme | RS-232 |
EasyPort | Festo Didactic GmbH & Co. KG | COM-Port / USB |
ROBO Interface | fischertechnik | RS-232 / USB |
ROBO TX Controller | fischertechnik | Bluetooth / USB |
HB627 | H-Tronic | USB |
ISM modules | Gantner | RS-232 |
UDAS 1001-E Series | Intelligent Instrumentation | Parallel |
DAQ BOOK series | IOtech | Parallel |
LabJack U3 | LabJack Corporation | USB |
LabJack U12 | LabJack Corporation | USB |
CASSY- und COM3LAB-System | LD Didactic GmbH | USB / RS-232 |
ProTrain, UniTrain, Universeller digital controller | Lucas-Nülle GmbH | USB / RS-232 |
ME-RedLab series | Meilhaus Electronic GmbH | USB |
EXDUL/XMOD-USB modules | Messcomp Datentechnik GmbH | USB |
Centurio-Feldbus modules | MKFCS | Ethernet |
myAVR MK2 | MyAVR | USB |
myDAQ | National Instruments | USB |
PMD series | Plug-In Electronic GmbH | RS-232 |
AVR-Net-IO-Board | POLLIN ELECTRONIC GmbH | RS-232 / Ethernet |
Bluetooth-I/O-Board MFC 4422-DC/EM | Reichelt Elektronik | Bluetooth |
TinkerForge modules | TinkerForge | USB |
USB Interface Board K8055 | Velleman Components NV | USB |
USB Interface Board K8061 | Velleman Components NV | USB |
Raspberry PI | LAN / WLAN |
Bleile Datentechnik Port Devices Driver Updater
Drivers for modules marked by can be downloaded free of charge from either the German or the English download area.
Drivers for automation systems and PLC

Module type | Manufacturer / Distributor |
---|---|
TwinCAT | Beckhoff Automation GmbH |
PLC S7 | Siemens |
WAGO I/O-System 750 | WAGO Kontakttechnik GmbH & Co. KG |
MODBUS | Diverse |
Driver for CAN-Bus
For the CAN-Bus which is especially popular in the automotive industry a BORIS driver is available, at first for the large range of PC-CAN interfaces from the PEAK-System company in Darmstadt. The driver enables the comfortable signal configuration and the reading and writing of any signals. Our video (German) demonstrates the use of the driver in conjunction with the PCAN-MicroMod Evaluation Kit from PEAK-System.
Bleile Datentechnik Port Devices Driver Download
Drivers for CONRAD digital multimeters
For the digital multimeters MS 9160, 3850 M, 3860 M, 4660 M, GDM 704/705, ME-22, ME-32, ME-42, VC 635, VC 655, VC 350, 4660 A, VC 820 and VC 840 of the company CONRAD-Elektronik low priced BORIS-drivers are available which allow measurement data acquisition, visualization and processing without any programming. Up to four multimeters (depending on the number of COM-ports of the PC) can be operated simultaneously. Details of the multimeters you find on the website of CONRAD-Elektronik.
Bleile Datentechnik Port Devices Driver Vga
Videos
Nutzung von I/O-Modulen unter BORIS am Beispiel des Velleman K8055-USB-Boards (German) |
Treiber für PCAN-MicroMod Evaluation Kit von PEAK-Systems (German) |
Treiber für 1-Wire-Temperatursensor DS1820 (German) |
Installation Instructions
Bleile Datentechnik Port Devices Driver Tp-link
Important installation instructions – please read carefully before you begin with the installation! For more information please read the PosterJet Support Guide.
- Install PosterJet only locally with Administrator privileges. NEVER install PosterJet via Remote Desktop!
- Deactivate User Account Controls during installation.
- Before the installation, make sure the hidden directory “C:Users
AppDataLocalMicrosoftMicrosoft SQL Server DataSQLEXPRESS” is deleted, if it exists (directory may be located somewhere else, depending on Windows operating system, if PosterJet has been installed previously). - Users without Administrator privileges MUST at least belong to the Power User Group (Standard User privileges are insufficient for running PosterJet).
- In order to successfully print via PosterJet virtual PPD-driver, special user privileges must be provided. Otherwise, jobs will not be forwarded from the Windows Printer Queue to the PosterJet Main or Nest Queue.
- When installing PosterJet under a 64Bit Operating System please make sure that the latest Safenet HASP HL Dongle driver is installed (to be downloaded from Safenet website www.safenet-inc.com). In some cases you must prevent Windows to install an “updated” version of the driver, as the Windows driver ISN’T working at all.
- When installing PosterJet under Microsoft “Internet Information Services” (IIS) on a 64Bit Operating System please make sure to ONLY install the 32Bit Version of PosterJet. The installation of PosterJet under a Server Operating System (e.g. Windows Server 2003, Windows Server 2008) requires the installation under IIS.
- When using a different TCP/IP-Port than Standard Port 80, the Client needs to be informed that the PosterJet Server uses such different Port (e.g. 81, 82 or 83). Otherwise the Client will not connect to the PosterJet Server after installation.